एक देखभाल करने वाला पेशेवर आपको बेहतर महसूस कराने के लिए
Valve-in-valve: a new valve inside a worn surgical valve
Tissue valves placed by surgery usually last 10 to 15 years. When one wears out, a new valve can often be fitted inside it through a catheter, without a second open-heart operation.
Medically reviewed by Dr. Srinivasa Prasad B V, MD, DM (Cardiology), FSCAI. Last reviewed November 2026.
Signs an old valve is failing
Breathlessness returning years after a valve operation, swelling of the feet, tiredness, or a new murmur heard by your doctor. An echo shows whether the valve has narrowed, started to leak, or both.
Why a second operation is harder
Repeat open-heart surgery means going through scar tissue from the first operation, usually at an older age and with more health problems than the first time. For many people that risk is high. Valve-in-valve uses the frame of the old valve as an anchor for the new one.
What decides whether it is possible
-
The make and size of your existing valve. Bring the original discharge summary or valve card if you have it. Small surgical valves leave less room for a new one.
-
Distance to the coronary arteries. The CT scan checks that the old valve leaflets will not block them when pushed aside.
-
Whether there is infection or a leak around the valve. These usually need surgery, not a catheter procedure.
Where the old valve is small, the frame can sometimes be cracked open with a high-pressure balloon to make more room. Where the coronary arteries are at risk, there are techniques to protect them, including splitting the old valve leaflet before the new valve is opened (BASILICA). These are planned from the CT before the day.
Mitral valve-in-valve and valve-in-ring
A worn surgical mitral valve, or a failed mitral repair ring, can be treated in a similar way through a vein at the groin, crossing to the left side of the heart. See mitral valve procedures.
Recovery and risks
Recovery is similar to a first TAVI: walking the next day and home in a few days for most people. The risks are those of TAVI, plus a higher chance that the new valve is a little tight because it sits inside the old one. That is why sizing from the CT matters so much.
Sources
-
Vahanian A, et al. 2021 ESC/EACTS Guidelines for the management of valvular heart disease. European Heart Journal, 2021.
-
Dvir D, et al. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves (VIVID registry). JAMA, 2014.